Changing the address – IBM VERSION 5 SY44-5902-05 User Manual

Page 148

Advertising
background image

For PowerPC-based IOPs, you set all four bytes of the address (

wwxx yyzz). Set ww

with the first use of function 59. Set

xx with the second use of function 59. Set the

yy with Function 60 and zz with Function 61 as described in “Changing the
address”.

Changing the address

For PowerPC-based IOPs: Setting the ww Position

:

1.

Press the Increment (

↑) or Decrement (↓) switch until 59 appears in the

Function display.

2.

Press Enter on the control panel; ** appears next to the function number.

3.

Press the Increment (

↑) or Decrement (↓) switch until the value of ww appears

next to the function number.

4.

Press Enter on the control panel.

5.

Press the Increment (

↑) or Decrement (↓) switch until ** appears next to the

function number (59**).

6.

Press Enter on the control panel.

To continue, follow the steps in “For Motorola** 68020 Processor-based IOPs”
below.

For Motorola** 68020 Processor-based IOPs: Setting the xx Position

:

1.

Press the Increment (

↑) or Decrement (↓) switch until 59 appears in the

Function display.

2.

Press Enter on the control panel; ** appears next to the function number.

3.

Press the Increment (

↑) or Decrement (↓) switch until the value of xx appears

next to the function number.

4.

Press Enter on the control panel.

5.

Press the Increment (

↑) or Decrement (↓) switch until ** appears next to the

function number (59**).

6.

Press Enter on the control panel.

Setting the yy Position

:

7.

Press the Increment (

↑) or Decrement (↓) switch until 60 appears in the

Function display.

8.

Press Enter on the control panel; ** appears next to the function number.

9.

Press the Increment (

↑) or Decrement (↓) switch until the value of yy appears

next to the function number.

10.

Press Enter on the control panel.

11.

Press the Increment (

↑) or Decrement (↓) switch until ** appears next to the

function number (60**).

12.

Press Enter on the control panel.

Setting the zz Position

:

13.

Press the Increment (

↑) or Decrement (↓) switch until 61 appears in the

Function display.

14.

Press Enter on the control panel; ** appears next to the function number.

15.

Press the Increment (

↑) or Decrement (↓) switch until the value of zz appears

next to the function number.

16.

Press Enter on the control panel. Record the data from the display as the base
address.

134

Service Functions V5R2