Chapter 7. Initial Program Load (IPL) Information

IPL type, mode, and speed options .

.

.

.

.

. 217

IPL speed recommendations

.

.

.

.

.

.

. 217

Methods to perform IPL .

.

.

.

.

.

.

.

.

. 217

Alternate installation IPL

.

.

.

.

.

.

.

.

. 218

IPL sequence

.

.

.

.

.

.

.

.

.

.

.

.

. 218

Service processor initialization.

.

.

.

.

.

. 218

Functions performed .

.

.

.

.

.

.

.

. 218

What is initialized .

.

.

.

.

.

.

.

.

. 218

Abnormal ending .

.

.

.

.

.

.

.

.

. 219

Licensed Internal Code (LIC) initialization.

.

. 219

Functions performed .

.

.

.

.

.

.

.

. 219

Abnormal ending .

.

.

.

.

.

.

.

.

. 219

Initialization output .

.

.

.

.

.

.

.

. 220

Data descriptions .

.

.

.

.

.

.

.

.

. 220

Log entries .

.

.

.

.

.

.

.

.

.

.

. 220

Status SRCs .

.

.

.

.

.

.

.

.

.

.

.

.

. 221

IPL type, mode, and speed options

Set the IPL options from function 02 on the control panel. To permanently change
the IPL speed use the

CHGIPLA command.

v Use function 01 to display the current IPL option, including IPL speed. This is

the option and speed that the system will use at the next IPL. Refer to “Function
01–Display Selected IPL Type and Speed (on Systems with a Keystick)” on
page 162
for more information about function 01.

v Refer to the information in Table 15 on page 159 for speed override definitions.
v Use the HDWDIAG (hardware diagnostics) parameter of the CHGIPLA command to

permanently change the IPL speed. The values are: The default shipped value

*MIN (minimal) for fast diagnostics and *ALL for all (full) diagnostics.

IPL speed recommendations

v Use CHGIPLA *MIN, or Function 02 F or V=F for most IPLs (to perform a fast IPL

that uses minimum diagnostics).

v Use CHGIPLA *ALL, or Function 02 S or V=S, if you change hardware or suspect an

intermittent hardware failure (to perform a slow IPL that uses all diagnostics).

v Use CHGIPLA *ALL, or Function 02 S or V=S during the first Install IPL. You can

set this at the panel with Function 02; it affects only the one IPL because the
next IPL will again pick up the value set with

CHGIPLA.

For more information about:
v IPL types, see Table 13 on page 159
v IPL modes, see Table 14 on page 159
v IPL speeds, see Table 15 on page 159
v Control panel functions, see “Control panel function descriptions (Models 150,

170, 250, 4xx, 50x, 51x, 530, 53S, 6xx, 7xx, SB1, and Sxx)” on page 162 or the
system operator information

Methods to perform IPL

Table 43. Methods to perform IPL

Methods

Description

POR

Power on reset IPL. The system was powered off and powered on. During the power on,
all hardware runs diagnostic tests.

© Copyright IBM Corp. 1997, 2002

217