IBM VERSION 5 SY44-5902-05 User Manual

Page 197

Advertising
background image

Table 33. SPCN functions in function 07 (continued)

AB

Support-directed procedure only.

AC

Support-directed procedure only.

Figure 79 shows the diagram for function A6 or A8 on a Non-System unit panel
and function A8 on a System unit panel..

3.

Use the Increment (

↑) or Decrement (↓) buttons to select the frame on which to

perform the function that you selected in step 2 on page 182. Press Enter.

4.

If you selected function A2, A3, A4, or A5 in step 2 on page 182, select the
appropriate fan or power supply listed in the following table to perform the
operation on.

Fans

Power supplies

00=B01, 01=B02, 02=B03, 03=B04

00=P01, 01=P02, 02=P03, 03=P04, 04=P05,
05=P06

5.

If you selected function A6 or A8 in step 2 on page 182:
v If a non-system unit address was selected in step 3, the non-system unit

display panel should be blinking and displaying data as shown in Figure 79.

v If a system unit address was selected in step 3, use the Increment (↑) or

Decrement (

↓) buttons to scroll to 07xx, where xx is the configuration ID.

The configuration IDs are defined as follows:

71 - xSeries Server Tower

80 - FC 5065/5066

81 - FC 5074/5079/8079

82 - FC 9079

83 - Model 830/SB2

84 - FC 5078/0578

89 - FC 5088/0588

8A - FC 5094/5294

8B - FC 5095

90 - FC 5075

91 - Model 270 CCIN 22A2, 22A4, 22A5, 2422 without FC 7104

92 - Model 270 CCIN 24A0, 24A2 without FC 7104

93 - Model 820 iSeries

95 - Model 270 CCIN 22A2, 22A4, 22A5, 2422 with FC 7104

96 - Model 270 CCIN 24A0, 24A2 with FC 7104

99 - FC 9094

6.

If you selected function A7 in step 2 on page 182, select either C1 to power ON
the frame or C2 to power OFF the frame.

7.

If you selected function A9 in step 2 on page 182:

Figure 79. Operations diagram for functions A6 and A8

Chapter 5. Control Panel Functions

183

Advertising