Table 9 on page 117 is generally reserved for engineering use. However, to get
additional information for IOP product activity log entries at DST when using a
D-IPL (which begins at offset hex

000180), see “More information from

hexadecimal reports” on page 117.

Table 7. Hexadecimal dump byte assignments for keyed data

Hexadecimal offset

Length in bytes

Description

0000

4

Internal release level

0004

4

Length of component specific data

0008

2

Non-keyed data start @

000A

2

Component specific start @

000C

8

Time stamp

0014

4

Sequence number

0018

1

Subsystem type

0019

1

Analysis done

001A

4

System log ID

001E

2

Reserved

0020

2

Reference code

0022

2

Reserved

0024

1

Class

0025

1

Reserved

0026

8

SRID

002E

2

Reserved

0030

4

Device type

0034

4

Model number

0038

10

Serial number

0042

4

IOP type

0046

4

I/O adapter type

004A

10

I/O processor direct select address

2

Transport type

2

Bus

2

Board

2

Card

2

Reserved

0054

12

Unit address

0060

4

Reserved

0064

6

Power address

006A

2

Reserved

006C

5

Card position

0071

5

Device position

0076

10

Reserved

0080

10

Network interface name

008A

10

Line name

0094

10

Controller description

009E

10

Device description

00A8

15

Reserved

00B7

1

Overlay flag

00B8

40

Volume ID/JOB information

Table 8. Hexadecimal dump byte assignments for non-keyed data

Hexadecimal offset

Length in bytes

Description

00E0

8

Reference code translate table (RCTT) name

00E8

2

Reserved

00EA

4

Product ID

116

Service Functions V5R2