IBM VERSION 5 SY44-5902-05 User Manual
Page 130

Table 9 on page 117 is generally reserved for engineering use. However, to get
additional information for IOP product activity log entries at DST when using a
D-IPL (which begins at offset hex
000180), see “More information from
hexadecimal reports” on page 117.
Table 7. Hexadecimal dump byte assignments for keyed data
Hexadecimal offset
Length in bytes
Description
0000
4
Internal release level
0004
4
Length of component specific data
0008
2
Non-keyed data start @
000A
2
Component specific start @
000C
8
Time stamp
0014
4
Sequence number
0018
1
Subsystem type
0019
1
Analysis done
001A
4
System log ID
001E
2
Reserved
0020
2
Reference code
0022
2
Reserved
0024
1
Class
0025
1
Reserved
0026
8
SRID
002E
2
Reserved
0030
4
Device type
0034
4
Model number
0038
10
Serial number
0042
4
IOP type
0046
4
I/O adapter type
004A
10
I/O processor direct select address
2
Transport type
2
Bus
2
Board
2
Card
2
Reserved
0054
12
Unit address
0060
4
Reserved
0064
6
Power address
006A
2
Reserved
006C
5
Card position
0071
5
Device position
0076
10
Reserved
0080
10
Network interface name
008A
10
Line name
0094
10
Controller description
009E
10
Device description
00A8
15
Reserved
00B7
1
Overlay flag
00B8
40
Volume ID/JOB information
Table 8. Hexadecimal dump byte assignments for non-keyed data
Hexadecimal offset
Length in bytes
Description
00E0
8
Reference code translate table (RCTT) name
00E8
2
Reserved
00EA
4
Product ID
116
Service Functions V5R2