Hardware configuration restrictions – IBM VERSION 5 SY44-5902-05 User Manual
Page 258

Table 46. Packaging resource naming formats (continued)
Name
Description
Example
DE
Device enclosure (rack-mounted)
DE01
EE
Card enclosure (enclosure-mounted)
EE01
EMD
Device (enclosure-mounted)
EMD01
EMP
Control panel (enclosure-mounted)
EMP01
FR
Frame
FR01
SD
Stand-alone device
SD001
SYS
System (packaging)*
SYS01
* A system resource (SYS) is a collection of all packaging resources that are
contained within, or attached to the system unit.
Hardware configuration restrictions
The following restrictions apply for the hardware that is associated with resources.
For more information, see Chapter 2, “Hardware Service Manager” on page 45 and
“Hardware information” on page 230.
v If you move a workstation I/O processor (IOP), you must move the attachment
cable that is connected to the IOP to the card position along with the IOP.
Note:
The cable must be moved because the configuration for the IOP is tied to
the resource name of the IOP, which follows the serial number of the card.
v If you move a communications I/O adapter (IOA), you must move the cables
that are connected to the IOA along with the IOA.
Note:
The cable must be moved because the configuration for the lines is tied to
the resource name of the IOA, which is based on the serial number of the
IOA card.
Communications card, cable, and wrap connector reference
Single-port communications adapter card and TPAC wrap
connector
Note:
TPAC = Two-Port Adapter Cable.
Table 47. Single-port communications adapter card wrap connector. This adapter wrap connector is also used for the
25-pin D shells on the two port adapter cable.
Communications adapter
card wrap connector
Connector pin
V.24-RS232 adapter
card
X.21 adapter card
V.35 adapter card
1 cable ID 3
1
CID 3
CID 3
CID 3
2 to 3
2
XD
XD-A
XD-A
3 to 2
3
RD
RD-A
RD-A
4 to 5
4
RTS
XD-B
XD-B
5 to 4
5
CTS
RD-B
RD-B
6 to 20
6
DSR
IND-A
Not Used
7
7
SGND
SGND
SGND
8 to 16,18
8
CD
SET-B
RX-A
244
Service Functions V5R2