Display system bus resources – IBM VERSION 5 SY44-5902-05 User Manual

Page 93

Advertising
background image

select the Display detail option (see “Display resource details” on page 73) to view
the resource status. This indicates the current status of the resource as reported by
the hardware.

Status values:
v Unknown - Cannot determine status. The resource may be non-reporting or

unable to communicate status.

v Operational - Resource is functioning normally.
v Failed - Resource has failed and is not functional.
v Errors - Card or device has detected errors but may still be functional.
v Not Connected - Functional connection to the card or device has been closed or

has failed. For bus resources, this condition indicates that wrap plugs are
installed.

v Degraded - Optical bus conditions indicating that the redundant path is being

used.

v Powered Off - Resource has been powered off or no power is being supplied to

the unit.

v Disabled - Resource has been reset or suspended. This is an I/O processor

status to indicate that the IOP is disabled except for bus level service or
maintenance (I/O debug functions). To recover from disabled status, perform
another IPL on the IOP (see “Debug the resource” on page 66 or “How to reset
an I/O processor card while the system is up and running” on page 295).

v Software Error — System licensed internal code associated with this hardware

resource has incurred a program exception.

Display serial/part numbers, logical address, and
status/resource name information

From packaging displays:

You can display serial and part number information on various Packaging
Hardware Resources displays by selecting the Display detail option (see “Display
resource details” on page 73).
To access address and status information from the
Packaging Hardware Resources displays, select the Associated logical resource(s)
option (see “Display associated resources” on page 67).

The Display serial/part numbers, Display logical address, and Display status/resource
name
function keys are available only on the Logical Hardware Resources displays.

From logical displays:

The Display serial/part numbers, Display logical address, and Display status/resource
name
function key is available only on the Logical Hardware Resources on System Bus
and Logical Hardware Resources Associated with IOP displays. This function key
toggles the display to show serial and part number information, logical address
information, or the default status and resource name.

For more information on status, see “Display resource status” on page 78.

Display system bus resources

From the Logical Hardware Resources display:

Chapter 2. Hardware Service Manager

79

Advertising