Table 38. General System Reference Codes (SRCs) (continued)

Problem

SRC

Description

B9xx xxxx

Operating system machine check (See iSeries OS/400 Diagnostic
Aids
)

Operator
intervention

A1xx xxxx

Operation interruption by service processor

A6xx xxxx

Operation intervention by LIC

A9xx xxxx

Operation interruption by operating system

IPL status

C1xx xxxx

IPL status for the service processor

C2xx xxxx

General status for normal LPAR power on

C3xx xxxx

IPL status for the system processor

C5xx xxxx

IPL status for system hardware initialization

C6xx xxxx

IPL status for LIC

C6xx 4400

Automatic main storage dump recovery (IPL) status

C6xx 441x

Automatic power failure recovery (IPL) status

C6xx 4500 through 4509

DST IPL status

C9xx xxxx

IPL status for OS/400 operating system program. See iSeries
OS/400 Diagnostic Aids

General status

D1xx xxxx

General status for the service processor

D2xx xxxx

General status for normal LPAR power off

D6xx xxxx

General status for Main Storage Dump Manager, LIC run-time
status, or LIC power off

D9xx xxxx

Power down status for OS/400 operating system program. See
iSeries OS/400 Diagnostic Aids

Word 2 - System status information

Word 2 provides a fixed location for information common to all SRCs shown on
the control panel. It is available for all SRC formats except power and control
panel. The service processor provides this information at the time the SRC is
displayed to the panel.

Notes for status indicators listed below:

1.

For the coding of M, Main storage dump indicator, see “Main Storage Dump
Indicator (M)”.

2.

For the coding of I, IPL state indicator, see “IPL State Indicator (I)” on page 195.

3.

For the coding of G, IPL type last initiated indicator, see “IPL Type Last
Initiated Indicator (G)” on page 195.

Status indicators

Main Storage Dump Indicator (M):

The first hexadecimal digit that is displayed

in Word 2 indicates whether the system started a main storage dump and if it was
successful. The indicator has the following meanings:

M

Description

0

Dump was not initiated

1

Debug data exists, destructive data only

2

Debug data exists, main storage only

3

Debug data exists, main storage and destructive data only

4

Debug data exists, partial dump (hardware data only)

5

Debug data exists, hardware and destructive data only

194