IBM VERSION 5 SY44-5902-05 User Manual

Page 200

Advertising
background image

Function 22–Dump Main Storage:

This function dumps main storage and

processor data to the disk.

Note:

Prior to pressing function 22, check to see whether function 34 is available
(

00 shows in the panel after you select function 34). If it is available, then

the system is attempting to run a main storage dump IPL. Using function 34
attempts to retry the IPL such that the original dump is not lost. If function
34 is not enabled (

>FF shows in the panel after you select function 34), go

back and start function 22.

The first time that you select function 22 and press Enter, the system displays
attention SRC 11 A1xx 3022. This indicates that you selected function 22. To dump
main storage and system processor data to the disk, you must select function 22
again and press Enter. See “Performing a main storage dump to disk (manual
MSD)” on page 271.

Use this function only when a main storage dump is necessary, for example, a
suspended (system hang) condition or after an operating system failure.

Attention:

No system shutdown is performed before the main storage dump. The

use of this function can cause loss of data. See “Function 34–Retry MSD IPL”.

Functions 25 and 26–Service Switches 1 and 2:

In function 25, the service

representative switch 1 is set. Function 25 is the first step necessary to set the
service function range (50 to 99).

In function 26, the service representative switch 2 is set. Function 26 is the second
step necessary to set the service function range (50 to 99).

Function 33–Reorder SPCN Addressing:

This function puts the rack addresses in

the correct order to show their position in the System Power Control Network
(SPCN). Use it when you have added racks to or removed them from the system.

Function 34–Retry MSD IPL:

Function 34 is enabled only for main storage dump

IPLs. You can use it when the system is hung during the MSD IPL to retry the IPL
without losing the original dump information.

Service Extended Panel Functions (Models 270, 8xx, SB2, SB3, 890)

Service functions 50 through 99 are enabled when you select Manual mode and
enter function 25 (service switch 1), then function 26 (service switch 2).
Subfunctions are used with Functions 51 and 57 through 64.

To enable functions 50 through 99:
1.

Select function 25 and press Enter. The display reads

25 00.

2.

Use the Increment button to select function 26 and press Enter. The display
reads

26 00.

Functions 50 through 99 are now available.

You can disable the service functions by selecting and entering either function 25
(service switch 1) or function 26 (service switch 2).

To disable functions 50 through 99, select function 25 and press Enter. Functions 50
through 99 are then no longer available.

186

Service Functions V5R2

Advertising