Frame, Unit, Type – IBM VERSION 5 SY44-5902-05 User Manual

Page 252: Model, Serial number, Load id, Reference code, Alert status, Extended status, Aros part number

Advertising
background image

The fields in this display have the following meanings:

Frame

This field shows the frame address.

Unit

This field shows the SPCN port number to which the rack-mounted unit is
connected. In models 270, 7xx, 8xx, SB2, and SB3, this field shows a 1, C, or 0.

Type

This field shows the product type of the unit.

Model

This field shows the model number of the unit.

Serial number

This field shows the serial number of the unit.

Load ID

This field shows the load identifier of the unit Licensed Internal Code.

Reference code

This field shows the error code for the unit. Starting with version 4 release 5, this
field will always be 0000.

Alert status

This field shows the status of the unit SPCN node.

Extended status

This field provides additional status information for the unit.

AROS part number

This field shows the alterable ROS part number.

Battery present

This field indicates whether a battery is present. Field values are

Yes or No. The

following four fields on battery information contain data when the field value is

Yes:

DisplayDetail for Unit

Frame . . . . . . . . . : 01

Load Id. . . . . . . . . . : 123FE305

Unit. . . . . . . . . . : 1

Reference code . . . . . . : 0000

Ty pe. . . . . . . . . . : 9902

Alert status . . . . . . . : 23

Model . . . . . . . . . : 001

Extended status. . . . . . : 142E

Serial number . . . . . : 10-2984631

AROS part number. . . . . . . . . . . . . . . : WS12948773JH

Batterypresent . . . . . . . . . . . . . . . : Yes

Last batterycapacitytest date . . . . . . . : 05/22/95 MM/DD/YY

Last batterycapacitytest time . . . . . . . : 10:53:02 HH:MM:SS

Next batterycapacitytest date . . . . . . . : 08/20/95 MM/DD/YY

Next batterycapacitytest time . . . . . . . : 10:53:02 HH:MM:SS

Power sequence complete . . . . . . . . . . . : Yes

Fault . . . . . . . . . . . . . . . . . . . . : No

Press Enter to continue.

F3=Exit F6=Displaystatus of regulators F12=Cancel