Battery capacity test, Frame, Unit – IBM VERSION 5 SY44-5902-05 User Manual
Page 248: Type

The fields in this display have the following meanings:
Battery capacity test
This field shows the status of the system-initiated periodic battery capacity test,
either enabled or disabled. When used with the F6 key, it allows you to enable or
disable the system-initiated periodic battery capacity test. If the field is already
enabled, F6 disables the battery capacity test. If the field is already disabled, F6
enables the battery capacity test. When the field is enabled, the test runs every
three months on each battery backup unit and any uninterruptible power supply
that supports CPM.
Opt
This field allows you to choose to work with the frame or unit components.
The following options are available for the Opt field:
v 3 (Write VPD)
For details on this option, see “Write Vital Product Data (VPD) option” on
page 235.
v 5 (Display detail)
For details on this option, see “Display Detail option” on page 236.
v 6 (Display trace log)
For details on this option, see “Display trace log” on page 239.
v 7 (Test battery interface)
For details on this option, see “Test battery option” on page 240.
Frame
This field refers to one of the system frames. The value is the SPCN address.
Unit
This field refers to one of the rack-mounted units that are connected to the SPCN.
The value is the SPCN port to which the unit is connected. A unit value of zero
indicates a system frame node. In V4R1 and later systems, the unit value is a 1, C,
or 0.
Type
This field shows the product type of the frame or unit.
System Power Control Network
Batterycapacitytest . . . . . . . : Enabled
Type options, press Enter.
3=Write VPD 5=Displaydetail 6=Displaytrace log
7=Test batteryinterface
Serial
Opt
Frame
Unit
Type
Number
Fault
_
01
0
....
00-00000
No
_
01
1
....
00-00000
No
_
02
0
5070
10-55555
No
_
02
1
5070
10-55555
No
_
03
0
....
00-00000
No
_
03
1
....
00-00000
No
_
04
0
....
00-00000
No
_
04
1
....
00-00000
No
_
05
0
....
00-00000
No
More...
F3=Exit
F5=Refresh
F12=Cancel
F6=Disable batterycapacitytest
234
Service Functions V5R2