EXAMPLE 4

To specify a new "PS" lock password, after the old password was disabled (e.g. after three failed attempts to

change the "PS" password): use the master phone code.

CAUTION: THIS TEST SHOULD BE PERFORMED ONLY IF THE CORRECT MASTER PHONE CODE FOR

THE INDIVIDUAL ME USED IS DEFINITELY AVAILABLE! Otherwise the module used will be rendered use-

less until the correct master phone code is entered!:

Alternatively, without giving a new password:

AT+CPWD="PS","12345678","1111"

where 12345678 is the Master Phone Code and

1111 is the new password. You may also use

<new

password>

to restore the former disabled pass-

word.

OK

AT+CPWD="PS","12345678"

(where 12345678 is the Master Phone Code). Deac-

tivates the present phone lock.

OK