11.15

ATA Manual response to a network request for PDP context acti-
vation

The V.250

ATA

command may be used to accept a network request for a PDP context activation announced by

the unsolicited result codes "

RING

" or "

+CRING

: GPRS". The MT responds with CONNECT, enters V.250 online

data state and follows the same procedure as it would after having received a

AT+CGANS

=1 with no

<L2P>

or

<cid>

values specified.

If you try to answer a request which is no longer present or which is already answered by another instance, NO

CARRIER is returned.