5 at+cgerep gprs event reporting – Siemens Brodersen MC55 AT User Manual

Page 273

Advertising
background image

MC55_ATC_V04.00

Page 273 of 475

3/17/06

Confidential / Released

11.5

AT+CGEREP GPRS event reporting

The write command enables or disables sending of unsolicited result codes, "

+CGEV

" from MT to TE in the case

of certain events occurring in the GPRS MT or the network.

<mode>

controls the processing of unsolicited result

codes specified within this command.

<bfr>

controls the effect on buffered codes when

<mode>

1 or 2 is

entered. If a setting is not supported by the MT, ERROR or +CME ERROR: is returned.

Read command returns the current

<mode>

and buffer settings.

Test command returns the modes and buffer settings supported by the MT as compound values.

Syntax

Unsolicited Result Codes

URC 1

+CGEV: REJECT

<PDP_type>

,

<PDP_addr>

A network request for PDP context activation occurred when the MT was unable to report it to the TE with a

+CRING unsolicited result code and was automatically rejected.

URC 2

+CGEV: NW REACT

<PDP_type>

,

<PDP_addr>

, [

<cid>

]

The network has requested a context reactivation. The

<cid>

that was used to reactivate the context is pro-

vided if known to the MT.

URC 3

+CGEV: NW DEACT

<PDP_type>

,

<PDP_addr>

, [

<cid>

]

The network has forced a context deactivation. The

<cid>

that was used to activate the context is provided

if known to the MT.

URC 4

+CGEV: ME DEACT

<PDP_type>

,

<PDP_addr>

, [

<cid>

]

The mobile equipment has forced a context deactivation. The

<cid>

that was used to activate the context is

provided if known to the MT.

Test Command

AT+CGEREP=?

Response(s)

+CGEREP:

(list of supported

<mode>

s), (list of supported

<bfr>

s)

OK

Read Command

AT+CGEREP?

Response(s)

+CGEREP:

<mode>

,

<bfr>

OK

Write Command

AT+CGEREP=

[

<mode>

[,

<bfr>

]]

Response(s)

OK

ERROR

+CME ERROR

Reference(s)

PIN

ASC0 ASC1

MUX1

MUX2

MUX3 Charge 

Last

GSM 07.07

%

%

%

%

%

%

!

!

!

Advertising