Serial interface control commands, 1 at\q flow control, Serial interface control commands 4.1 – Siemens Brodersen MC55 AT User Manual

Page 85: At\q flow control, At\q, Ed to

Advertising
background image

MC55_ATC_V04.00

Page 85 of 475

3/17/06

Confidential / Released

4.

Serial Interface Control Commands

The AT Commands described in this chapter allow the external application to determine various settings related

to the MC55's serial interface.

4.1

AT\Q Flow control

Syntax

Parameter Description

[0]

(&F)

Disable flow control

1

XON/XOFF software flow control

2

Only CTS by DCE (TA)

3

RTS/CTS hardware flow control

Recommended for the following procedures: incoming or outgoing data calls,

fax calls, MUX mode.

Often, the initialization routine of Fax programs includes enabling RTS/CTS

handshake, eliminating the need to issue

AT\Q

3 once again.

Notes

• When using XON/XOFF flow control (

AT\Q

1) in online mode,

+++

should not be used while the data trans-

mission is paused with XOFF. Before entering the command mode with

+++

the paused transmission should

be resumed using the XON character.

• For compatibility reasons, the

AT\Q

command can be used in Multiplex mode, though the settings will not

take effect. However, be aware that whenever you use the

AT\Q

write command in Multiplex mode and then

save the current configuration to the user profile with

AT&W

, the changed

AT\Q

setting will become active after

restart.

Exec Command

AT\Q

[

<n>

]

Response(s)

OK
If RTS/CTS flow control is not supported by interface and

<n>

is 2 or 3:

ERROR

Reference(s)

PIN

ASC0 ASC1

MUX1

MUX2

MUX3 Charge 

Last

SIEMENS

!

%

%

§

§

§

!

!

!

<n>

(num)(&W)(&V)

Advertising