1 wake up the me from sleep mode, Wake up the me from sleep mode, Table 2.3 – Siemens Brodersen MC55 AT User Manual

Page 40

Advertising
background image

MC55_ATC_V04.00

Page 40 of 475

3/17/06

Confidential / Released

When, for example, an SMS is being received and indicated by an unsolicited result code (URC), the ME

wakes up to full operation.

After this, you may want to verify the operating status:

EXAMPLE 3

To stop CYCLIC SLEEP mode and return to full functionality:

Remember that this approach is not applicable to the NON-CYCLIC SLEEP mode (since the serial interface

is disabled). The NON-CYCLIC SLEEP mode ends with the first wake-up event.

EXAMPLE 4

To reset and restart the ME:

2.8.1

Wake up the ME from SLEEP mode

A wake-up event is any event that causes the ME to draw more current. Depending on the selected mode, the

wake-up event either switches the SLEEP mode off and takes the ME back to full functionality

AT+CFUN

=1, or

activates the ME temporarily without terminating the selected SLEEP mode.

Definitions of the state transitions described in Table

2.3

:

• Quit: ME exits SLEEP mode.
• Temporary: ME becomes active temporarily for the duration of the event and the mode-specific follow-up time

after the last character was sent or received on the serial interface.

• No effect: Event is not relevant in the selected SLEEP mode. The ME does not wake up.

Table 2.3: Wake-up events in NON-CYCLIC and CYCLIC SLEEP modes

+CMTI: "SM",5

Note that the URC used in this example will appear only, if

AT+CNMI

=1,1 was configured before.

AT+CFUN?

+CFUN: 1

Indicates that ME has entered full functionality mode.

AT+CFUN?

+CFUN: 5

OK

AT+CFUN=1

OK

AT+CFUN=1,1

or alternatively, AT+CFUN=0,1 or 5,1 or 6,1 or 7,1 or 8,1 or 9,1

OK

^SYSSTART

The ^SYSSTART URC confirms that the ME has been rebooted. Note

that ^SYSSTART appears only if

AT+IPR

≠ 0. If the ME is in autobaud

mode, it is recommended to wait 3 to 5 seconds before entering the first

AT command. Remember to enter the SIM PIN after restart.

Event

Selected mode:

<fun>

=0

Selected mode:

<fun>

=5 or 6

Selected mode:

<fun>

=7 or 8 or 9

Ignition line

No effect

No effect

No effect

/RTS0 or /RTS1 activation Quit

No effect (RTS is only

used for flow control)

Mode 7 and 8: No effect

(RTS is only used for flow

control)

Mode 9: Temporary

Unsolicited Result Code

(URC)

Quit

Quit

Temporary

Incoming voice or data

call

Quit

Quit

Temporary

Advertising