9 ath disconnect existing connection, Ath disconnect existing connection – Siemens Brodersen MC55 AT User Manual

Page 136

Advertising
background image

MC55_ATC_V04.00

Page 136 of 475

3/17/06

Confidential / Released

7.9

ATH Disconnect existing connection

Syntax

Command Description

Disconnect existing call from command line by local TE and terminate call.

Parameter Description

[0]

disconnect from line and terminate call

Notes

• OK is issued after circuit 109 (DCD) is turned off, if it was previously on.

ATH

terminates every circuit switched call (voice, data or fax), even if it is issued via another interface. This

behavior is in accordance with ITU-T V.250; (07/97, "Hook control": "

ATH

is terminating any call in progress.").

ATH

clears any active PDP context or terminates any existing PPP connection, but only if issued on the same

interface where GPRS is used and if there is no pending network request for PDP context activation. It does

not affect PDP contexts and PPP connections on other interfaces (see also Chapter "

ATH

Manual rejection

of a network request for PDP context activation").

Exec Command

ATH

[

<n>

]

Response(s)

OK

Reference(s)

PIN

ASC0 ASC1

MUX1

MUX2

MUX3 Charge 

Last

V.250

!

%

%

%

%

%

!

!

!

<n>

(num)

Advertising