3-7. Installing the Ceiling Panel

(1) Lift the ceiling panel and position it to align the

panel hook with the panel catch of the indoor unit.

The ceiling panel must be mounted in the correct direc-

tion. Note that the 2 catches of the panel differ in size.

Confirm that the catches are correctly matched

between the ceiling panel and the indoor unit body.

(2) Next, check to see that the ceiling panel is prop-

erly aligned with the seamline of the ceiling. If it is

not, remove the ceiling panel and slightly readjust

the indoor unit body to the proper suspension

point.

(3) When the ceiling panel has been properly aligned,

use the supplied 4 mounting screws (M5) with

washers to permanently fasten the ceiling panel.

(4) Install the wiring connector from the ceiling panel

to the connector in the electrical component box of

the indoor unit. After installing the connector, use

the clamp on the body of the indoor unit to secure

the wiring.

(5) Install the air filter and air-intake grille by perform-

ing the steps in section 3-6 in reverse.

Rehook the safety cord before closing the air-intake

grille.

3-8. When Removing the Ceiling Panel

for Servicing

When removing the ceiling panel for servicing, remove

the air-intake grille and air filter, disconnect the wiring

connector inside the electrical component box, and then

remove the 4 mounting screws.

NOTE

NOTE