K

(1) Shape the refrigerant tubing so that it can easily go into

the wall hole. (Fig. 3-62)

CAUTION

If using a stepladder, be careful to

keep your balance and not fall off.

To prevent the unit from damage

and avoid personal injury, ask for

someone’s help when feeding the

tubing through the hole because

the unit is heavy and difficult to

hold in place.

(2) Push the wiring, refrigerant tubing, and drain hose

through the hole in the wall. Adjust the indoor unit so it is

securely seated on the rear panel.

(3) Carefully bend the tubing (if necessary) to run along the

wall in the direction of the outdoor unit and then tape as

far as the fittings.

(4) Connect the refrigerant tubing to the outdoor unit. (After

performing a leak test on the connecting part, insulate it

with tubing insulation. (Fig. 3-64)) Also, refer to Section

10-5. Connecting Tubing between Indoor and Outdoor

Units.

(5) Assemble the refrigerant tubing, drain hose, and

inter-unit wiring as shown in Fig. 3-65.

(1) Shape the narrow refrigerant tube and drain

hose in the desired direction so that they can

easily go into the wall hole. (Fig. 3-66)

(2) Push the wiring, narrow tube, and drain hose

through the hole in the wall.

(3) Bend the tubing (if necessary) to run along the wall in

the direction of the outdoor unit, then tape as far as the

fittings. The drain hose should come straight down the

wall to a point where water runoff won't stain the wall.

(4) Hang the indoor unit on the wall fixture. (Fig. 3-67)

(5) Install the mounting plate to secure the indoor unit

solidly to the wall. The plate can be positioned in either

of the 2 ways shown. (Fig. 3-68)

CAUTION

The air conditioner’s performance

will deteriorate if a tube is crushed.

To prevent crushing of tubing,

avoid sharp bends. Use a pipe

bending tool to bend tubes.

(Fig. 3-63)

Cover

Refrigerant
tubing

Drain hose

Inter-unit
wiring

Fig. 3-62

Pipe bending tool

a

b

b / a = 0.7 or more

Fig. 3-63

Insulation
(Field supply)

Fig. 3-64

Refrigerant tubing

Drain hose

Conduit

Inter-unit wiring

Fig. 3-65