42

K

Tubing can be extended in 4 directions as shown in

Fig. 3-54.

Arrangement for Left Tubing

(a) Cut out the left tubing outlet. (Fig. 3-55)

Arrangement for Right Tubing

(a) Cut out the right tubing outlet using a hacksaw.

(Fig. 3-56)

Arrangement for Left-rear and Right-rear Tubing

(a) It is not necessary to cut a hole.

3-15. Wiring Instructions

General Precautions on Wiring

(1) Before wiring, confirm the rated voltage of the

unit as shown on its nameplate, then carry out

the wiring closely following the wiring diagram.

(2) Provide a power outlet to be used exclusively for

each unit. A power supply disconnect and circuit

breaker for overcurrent protection should be

provided in the exclusive line.

(3) To prevent possible hazards from insulation

failure, the unit must be grounded.

(4) All wiring must be connected tightly.

(5) Do not allow wiring to touch refrigerant tubing,

compressor, or any moving parts of the fan.

KHH(S)2672R

Left-rear
tubing

Left
tubing

Right-rear
tubing
(Recommended)

Right tubing

Fig. 3-54

Fig. 3-55

Fig. 3-56

Unauthorized changes in the

internal wiring can be very

dangerous. The manufacturer

will accept no responsibility for

any damage or misoperation

that occurs as a result of such

unauthorized changes.

Right tubing
outlet

Left tubing
outlet