WARNING

Loose wiring may cause the
terminal to overheat or result
in unit malfunction. A fire
hazard may also exist.
Therefore, ensure that all

wiring is tightly connected.

When connecting each power wire to the correspond-

ing terminal, follow the instructions on “How to connect

wiring to the terminal” and fasten the wire securely with

the fixing screw of the terminal plate.

5-4. How to Connect Wiring to the Terminal

For stranded wiring

(1) Cut the wire end with a wire cutter or wire-cutting

pliers, then strip the insulation to expose the

stranded wiring about 3/8 in. (Fig. 5-1)

(2) Using a Phillips head screwdriver, remove the ter-

minal screw(s) on the terminal plate.

(3) Using a ring connector fastener or pliers, securely

clamp each stripped wire end with a ring pressure

terminal. (Fig. 5-1)

(4) Place the ring pressure terminal, and replace and

tighten the removed terminal screw using a

screwdriver. (Fig. 5-2)

Fig. 5-1

Stranded wire

Ring
pressure
terminal

.

ni

8/

3

pir

t

S

Fig. 5-2

Wire

Special
washer

Screw

Ring pressure
terminal

Terminal plate

Screw and
Special washer

Ring
pressure
terminal

Wire