One hole is required for the air conditioner tubing, and

may be either on the left or right side. (Also see section

3-14. Preparing the Indoor Side Tubing.)

(1) Tape the full-scale installation diagram on the wall

at the location selected. Make sure the unit is

horizontal using a level or tape measure to

measure down from the ceiling. (Fig. 3-25)

(2) Determine if the hole is to be drilled at the left or

right hole location.

(3) Before drilling a hole, check that there are no

studs or pipes behind the determined location.

KH(S)3072R, KH(S)3672R

CAUTION

Avoid any area where electrical

wiring or conduit is located.

Also take this precaution if the

tubing goes through a wall at

any other location.

(4) Using a sabre saw, key hole saw or 3-5/32 in.

hole-cutting drill attachment, make a hole in the

wall. The required minimum hole diameter for

these models is 3-3/16 in. (Fig. 3-26)

(5) Measure the thickness of the wall from the inside

edge to the outside edge and cut PVC pipe at a

slight angle 1/4 in. shorter than the thickness of

the wall. (Fig. 3-27)

(6) Place the plastic cover over the end of the pipe,

(for indoor side only) and insert in the wall.

(Fig. 3-28)

Tape

Full-scale
installation diagram

Fig. 3-25

Indoor
side

Outdoor
side

Fig. 3-26

Cut at slight angle

PVC pipe (locally purchased)

Fig. 3-27

Plastic
cover

INSIDE

Wall

Slight
angle

PVC pipe

OUTSIDE

Fig. 3-28

NOTE

Hole should be made at a slight downward slant to

the outdoor side.