(1) Insert the inter-unit wiring (according to local

codes) into the through-the-wall PVC pipe. Run the

wiring toward the indoor side allowing approx. 5" to

extend from the wall face.

(Figs. 3-59a and 3-59b)

KHH(S)2672R

CAUTION

Never fix the wiring by any

means before the indoor unit is

fully seated on the rear panel.

(2) Remove the side cover and the metallic cover.

(Fig. 3-60 or 3-61, depending on model.)

(3) Secure the conduit connector to the chassis with a

lock nut. (Fig. 3-60 or 3-61)

(4) Give some play to the inter-unit wiring from the

outdoor unit to the corresponding terminals on the

terminal plate.

(5) Secure the metallic cover with its screw. Then

replace the side cover.

CAUTION

Be sure to refer to the wiring
system diagram label inside
the metallic cover and carry
out the correct field wiring.
Wrong wiring can cause the
unit to malfunction.

Check local electrical codes
and any specified wiring
instructions or limitations.

KH(S)3072R, KH(S)3672R

Fig. 3-59b

Grounding
line

Power line

Screw

Plastic cover

Metallic cover

Lock
nut

Elbow
conduit

Look nut

Lock
nut

Connector

Metallic cover

Side cover

Fig. 3-60

Fig. 3-61