Mode 1 output timing, Mode 1 output timing -7 – National Instruments Data Acquisition Device E Series User Manual

Page 102

Advertising
background image

Chapter 4

Digital I/O

© National Instruments Corporation

4-7

E Series User Manual

Mode 1 Output Timing

(NI 6016 and NI 6025E Devices Only)

Figure 4-4 and Table 4-4 show timing

specifications for an output transfer in mode 1.

Figure 4-4. Output Transfer in Mode 1 Timing Specifications

Table 4-4. Output Transfer in Mode 1 Timing Specifications

Name

Description

Minimum (ns)

Maximum (ns)

T1

WR* = 0 to INTR = 0

250

T2

WR* = 1 to Output

200

T3

WR* = 1 to OBF* = 0

150

T4

ACK* = 0 to OBF* = 1

150

T5

ACK* Pulse Width

100

T6

ACK* = 1 to INTR = 1

150

WR*

OBF*

INTR

ACK*

DATA

T1

T2

T3

T4

T5

T6

WR*

OBF*

INTR

ACK*

DATA

T1

T2

T3

T4

T5

T6

Advertising