+5 V Power Source

The +5 V pins on the I/O connector supply +5 V power on the plug-in cards
or from an internal step-down voltage regulator on DAQPads. You can
use these pins, referenced to D GND, to power external circuitry. A
self-resetting fuse protects the supply from overcurrent conditions. The
fuse resets automatically within a few seconds after the overcurrent
condition is removed.

Power rating (most devices): +4.65 to +5.25 VDC at 1 A.

To find your device power rating, refer to the specifications document for
your device.

Caution

Never connect these +5 V power pins to analog or digital ground or to any other

voltage source on the E Series device or any other device. Doing so can damage the device
and the computer. NI is not liable for damage resulting from such a connection.