Figure 2-14. ni-daqmx create virtual channel.vi, Analog input timing signals, Analog input timing signals -30 – National Instruments Data Acquisition Device E Series User Manual

Page 63

Advertising
background image

Chapter 2

Analog Input

E Series User Manual

2-30

ni.com

Figure 2-14. NI-DAQmx Create Virtual Channel.vi

Analog Input Timing Signals

In order to provide all of the timing functionality described throughout this
section, the DAQ-STC provides an extremely powerful and flexible timing
engine. Figure 2-15 summarizes all of the clock routing and timing options
provided by the analog input timing engine.

Figure 2-15. Analog Input Timing Engine Clock Routing and Timing Options.

E Series devices use the ai/SampleClock and ai/ConvertClock signals to
perform interval sampling. As Figure 2-16 shows, ai/SampleClock controls
the sample period, which is determined by the following equation:

1/sample period = sample rate

÷

200

RTSI 7

20 MHz

Timebase

Onboard

Clock

PFI 0–9,

RTSI 0–6

Onboard

Clock

ai/SampleClock

Timebase

ai/SampleClock

Ctr0InternalOutput

PFI 0–9,

RTSI 0–6

Divisor

Master

Timebase

Onboard

Clock

Divisor

ai/ConvertClock

Timebase

PFI 0–9,

RTSI 0–6

Ctr0InternalOutput

ai/Convert

Clock

ч

ч

Advertising