background image

Chapter 8

Real-Time System Integration Bus (RTSI)

© National Instruments Corporation

8-3

E Series User Manual

plugged into Slot 2 of the chassis. E Series devices can accept timing
signals from the PXI star trigger line, but they cannot drive signals onto it.
For more information about the star trigger, refer to the PXI Hardware
Specification Revision 2.1
.

Figure 8-2. PXI E Series Signal Connection Scheme

Refer to the

Timing Signal Routing

section of Chapter 7,

Digital Routing

,

for a description of the signals shown in Figure 8-2.

Note

In NI-DAQmx, you can indirectly route timing signals not shown in the above

diagrams to RTSI. For a detailed description of which routes are possible on your device,
in MAX, select Devices and Interfaces, your device, then select the Device Routes tab.

6

PXI Bus Connector

PXI Trigger 7

DAQ-STC

ai/StartTrigger

ai/ReferenceTrigger

ao/SampleClock

ao/StartTrigger

Ctr0Source

Ctr0Gate

Ctr0InternalOutput

Ctr0Out

ai/SampleClock

ai/PauseTrigger

ai/SampleClockTimebase

ao/SampleClockTimebase

Ctr1Source

Ctr1Gate

20MHz Timebase

Master Timebase

R

T

SI Switch

Switch

PXI Trigger <0..5>

PXI Star 6

ai/ConvertClock

ao/PauseTrigger