Chapter 3

Analog Output

© National Instruments Corporation

3-9

E Series User Manual

Waveform Generation Timing Signals

There is one AO Sample Clock that causes all AO channels to update
simultaneously. Figure 3-5 summarizes the timing and routing options
provided by the analog output timing engine.

Figure 3-5. Analog Output Timing Engine

AO Start Trigger Signal

You can use the AO Start Trigger (ao/StartTrigger) signal to initiate a
waveform generation. If you do not use triggers, you begin a generation
with a software command.

Using a Digital Source

To use ao/StartTrigger, specify a source and an edge. The source can be an
external signal connected to any PFI or RTSI <0..6> pin. The source can
also be one of several internal signal on your DAQ device. Refer to Device
Routing in MAX
in the NI-DAQmx Help or the LabVIEW 8.x Help for more
information.

Figure 3-6 shows the timing requirements of the ao/StartTrigger digital
source.

Figure 3-6. ao/StartTrigger Digital Source Timing Requirements

RTSI 7

20 MHz

Timebase

÷

200

Master

Timebase

Onboard

Clock

PFI 0–9,

RTSI 0–6

ao/SampleClock

Timebase

Onboard

Clock

Divisor

ao/SampleClock

Ctr1InternalOutput

PFI 0–9,

RTSI 0–6

÷

Rising-Edge

Polarity

Falling-Edge

Polarity

t

w

t

w

= 10 ns minimum