Counter 0 internal output signal, Figure 5-5. ctr0internaloutput signal behavior, Counter 0 internal output signal -5 – National Instruments Data Acquisition Device E Series User Manual

Page 110

Advertising
background image

Chapter 5

Counters

© National Instruments Corporation

5-5

E Series User Manual

Counter 0 Internal Output Signal

The Counter 0 Internal Output (Ctr0InternalOutput) signal is the output of
Counter 0. This signal reflects the terminal count (TC) of Counter 0. The
counter generates a terminal count when its count value rolls over. The
two software-selectable output options are pulse on TC and toggle output
polarity on TC. The output polarity is software-selectable for both options.
Figure 5-5 shows the behavior of the Ctr0InternalOutput signal.

Figure 5-5. Ctr0InternalOutput Signal Behavior

You can use Ctr0InternalOutput in the following applications:

•

In pulse generation mode, the counter drives Ctr0InternalOutput with
the generated pulses. To enable this behavior, software configures the
counter to toggle Ctr0InternalOutput on TC.

•

Ctr0InternalOutput can control the timing of analog input acquisitions
by driving the following signals:

–

ai/SampleClock

–

ai/StartTrigger

–

ai/ConvertClock

•

Counter 0 and 1 can be daisy-chained together by routing
Ctr0InternalOutput to Ctr1Gate.

•

Ctr0InternalOutput can drive any of the RTSI <0..6> signals to control
the behavior of other devices in the system.

•

Ctr0InternalOutput drives the CTR 0 OUT pin to trigger or control
external devices.

•

Ctr0InternalOutput can drive other internal signals.

Refer to Device Routing in MAX in the NI-DAQmx Help or the
LabVIEW 8.x Help for more information.

Ctr0Source

Ctr0InternalOutput

(Pulse on TC)

Ctr0InternalOutput

(Toggle Output on TC)

TC