Counter 0 internal output signal, Figure 5-5. ctr0internaloutput signal behavior, Counter 0 internal output signal -5 – National Instruments Data Acquisition Device E Series User Manual

Page 110

Advertising
background image

Chapter 5

Counters

© National Instruments Corporation

5-5

E Series User Manual

Counter 0 Internal Output Signal

The Counter 0 Internal Output (Ctr0InternalOutput) signal is the output of
Counter 0. This signal reflects the terminal count (TC) of Counter 0. The
counter generates a terminal count when its count value rolls over. The
two software-selectable output options are pulse on TC and toggle output
polarity on TC. The output polarity is software-selectable for both options.
Figure 5-5 shows the behavior of the Ctr0InternalOutput signal.

Figure 5-5. Ctr0InternalOutput Signal Behavior

You can use Ctr0InternalOutput in the following applications:

In pulse generation mode, the counter drives Ctr0InternalOutput with
the generated pulses. To enable this behavior, software configures the
counter to toggle Ctr0InternalOutput on TC.

Ctr0InternalOutput can control the timing of analog input acquisitions
by driving the following signals:

ai/SampleClock

ai/StartTrigger

ai/ConvertClock

Counter 0 and 1 can be daisy-chained together by routing
Ctr0InternalOutput to Ctr1Gate.

Ctr0InternalOutput can drive any of the RTSI <0..6> signals to control
the behavior of other devices in the system.

Ctr0InternalOutput drives the CTR 0 OUT pin to trigger or control
external devices.

Ctr0InternalOutput can drive other internal signals.

Refer to Device Routing in MAX in the NI-DAQmx Help or the
LabVIEW 8.x Help for more information.

Ctr0Source

Ctr0InternalOutput

(Pulse on TC)

Ctr0InternalOutput

(Toggle Output on TC)

TC