Master offset, Master offset -17 – National Instruments NI-Motion User Manual

Page 139

Advertising
background image

Chapter 10

Electronic Gearing and Camming

© National Instruments Corporation

10-17

NI-Motion User Manual

Master Offset

If the material and welding point are not initially aligned, as shown in
Figure 10-16, the master offset must be applied to consider the position
difference.

Figure 10-16. Misaligned Material and Welding Point

Without the master offset, the master device position is already inside the
first interval as soon as the first material passes the welding point.

Figure 10-16 shows that the master cycle intervals are offset by 50 counts.
The master interval is shifted from 0, 2,000, 4,000, and 6,000 to 50, 2,050,
4,050, and 6,050.

Position = 50

Position = 0

When there is no master offset,
the master cycle begins at
position 0.