You can calculate this minimum velocity increment in RPM with the
following formula:

where

Vmin = 1/65,536 counts/sample or steps/sample

Ts = sample period in seconds per sample

60 = number of seconds in a minute

R = counts or steps per revolution

or

You also can calculate the minimum velocity using the formula shown in
the

Calculation Based on Units

column in Table 4-1.

For a typical servo axis with 2,000 counts per revolution operating at a
250 µs update rate, the minimum RPM increment is

or

You can calculate the maximum velocity in RPM with the following
equation:

where

Vmax = 20 MHz for servos

8 MHz for steppers on a NI 7350 controller

4 MHz for steppers on a NI 7330, NI 7340, or NI 7390
motion controller

R = counts/steps per revolution

minimum RPM

Vmin

1

Ts

-----

 

 

Ч

60

Ч

1

R

---

 

 

×

=

minimum RPM

MIN

1

R

---

×

=

1

65,536

----------------

1

250

µs

----------------

Ч

60

1

2000

------------

Ч

Ч

0.00183105 RPM

=

3.662109

1

2000

------------

×

0.00183105 RPM

=

maximum RPM

Vmax 60

×

1

R

---