Chapter 14

Onboard Programs

NI-Motion User Manual

14-12

ni.com

LabVIEW Code

Figure 14-7. Onboard Program Waiting for an I/O Line to Go Active

C/C++ Code

The following example code is not necessarily complete, and may
not compile if copied exactly. Refer to the

examples

folder on the

NI-Motion CD for files that are complete and compile as is.

// Main Function

void main(void)

{

u8

boardID;// Board identification number

u8

axis;// Axis number

u16

csr = 0;// Communication status register

//Variables for modal error handling

u16

commandID;// The commandID of the function

u16

resourceID;// The resource ID

i32

errorCode;// Error code

///////////////////////////////

1

Begin Program
Storage

2

Set Operation Mode

3

Load Velocity in RPM

4

Load Target Position

5

Select MOMO

6

Wait on Condition

7

Start Motion

8

End Program Storage

9

Motion Error Handler

6

1

2

4

5

9

8

7

3