Straight-Line Moves

© National Instruments Corporation

5-21

NI-Motion User Manual

// Set the deceleration for the move (in

counts/sec^2)

err = flex_load_acceleration(boardID, axis,

NIMC_DECELERATION, 100000, 0xFF);

CheckError;

// Set the jerk (s-curve value) for the move (in

sample periods)

err = flex_load_scurve_time(boardID, axis, 100,

0xFF);

CheckError;

// Set the operation mode to velocity

err = flex_set_op_mode(boardID, axis,

NIMC_VELOCITY);

CheckError;

// Start the move

err = flex_start(boardID, axis, 0);

CheckError;

// Wait for the time for first segment

initialTime = timeGetTime();

do

{

// Check the following error/axis off status

err = flex_read_axis_status_rtn(boardID, axis,

&axisStatus);

CheckError;

// Read the communication status register and

check the modal //errors

err = flex_read_csr_rtn(boardID, &csr);

CheckError;

// Check the modal errors

if

(csr & NIMC_MODAL_ERROR_MSG)

{

err = csr & NIMC_MODAL_ERROR_MSG;

CheckError;

}

// Get the current time and check if time is over

for the first //segment

currentTime = timeGetTime();

if

((currentTime - initialTime) >= moveTime1)

break;

Sleep (100); //Check every 100 ms