Chapter 5

Straight-Line Moves

© National Instruments Corporation

5-19

NI-Motion User Manual

LabVIEW Code

Figure 5-8. Velocity-Based Move Using Velocity Override in LabVIEW

1

Load Velocity

2

Load Acceleration/Deceleration

3

Load Acceleration/Deceleration

4

Load S-Curve Time

5

Set Operation Mode

6

Start Motion

7

Read per Axis Status

8

Load Velocity Override

9

Read per Axis Status

10 Stop Motion
11 Motion Error Handler

4

1

2

3

6

9

7

10

11

5

8

Advertising