Table 4-2. acceleration update rate in counts/sec2, Ni 73 xx, Acceleration in counts/s – National Instruments NI-Motion User Manual

Page 49

Advertising
background image

Chapter 4

What You Need to Know about Moves

NI-Motion User Manual

4-8

ni.com

You can calculate the maximum velocity with the following equation:

where

Vmax = 20 MHz for servos

8 MHz for steppers on a NI 7350 controller

4 MHz for steppers on a NI 7330, NI 7340, or NI 7390
motion controller

and is constrained by acceleration/deceleration according to the following
equation:

velocity

≤ (65,536 × deceleration) – acceleration

where velocity is in counts/sample and acceleration and deceleration are in
counts/sample

2

.

NI 73xx

Acceleration in Counts/s

2

Acceleration and deceleration values are converted to an internal
16.16 fixed-point format in units of counts/s

2

before being used by the

trajectory generator.

Table 4-2 shows the minimum and maximum acceleration update rates in
counts/sec

2

.

Table 4-2. Acceleration Update Rate in Counts/Sec

2

Update Rate

MAX

MIN

Calculation Based

on Units

62.5 µs

2,048,000,000 counts/sec

2

3906 counts/sec

2

Accel

max

= MAX

125 µs

2,048,000,000 counts/sec

2

977 counts/sec

2

187.5 µs

910,222,222 counts/sec

2

434 counts/sec

2

250 µs

512,000,000 counts/sec

2

244 counts/sec

2

312.5 µs

327,680,000 counts/sec

2

156 counts/sec

2

Accel

min

= MIN

375 µs

227,555,556 counts/sec

2

109 counts/sec

2

437.5 µs

167,183,673 counts/sec

2

80 counts/sec

2

500 µs

128,000,000 counts/sec

2

61 counts/sec

2

maximum velocity

Vmax

=

Advertising