Ni 73xx time base, Table 4-1. velocity in counts/min, Ni 73 xx time base -5 – National Instruments NI-Motion User Manual

Page 46: Ni 73 xx time base, Ni 73 xx

Advertising
background image

Chapter 4

What You Need to Know about Moves

© National Instruments Corporation

4-5

NI-Motion User Manual

NI 73xx Time Base

Velocity and acceleration values are loaded in counts/s, RPM, RPS/s,
steps/s, and so on, which are all functions of seconds or minutes. However,
the trajectory generator updates target position at the Trajectory Update
Rate, which is programmable with the Enable Axes function. This means
that the range for these parameters depends on the update rate selected, as
shown in the following examples.

Table 4-1 lists minimum and maximum update rates for acceleration and
velocity in various units.

NI 73xx

Velocity in RPM

Velocity values in RPM are converted to an internal 16.16 fixed-point
format in units of counts (steps) per sample period (update period) before
being used by the trajectory generator. NI-Motion can control velocity to
1/65,536 of a count or step per sample.

Table 4-1 shows the minimum and maximum velocity in counts/min. Use
the formula shown in the Calculation Based on Units column to determine
the counts/min value to RPM.

Table 4-1. Velocity in Counts/Min

Update Rate

MIN

MAX

Calculation Based

on Units

62.5 µs

14.648438 counts/min

For servo motors, the
maximum counts/min is
1.2 billion independent
of the update rate.

±RPM

max

= MAX×1/r

where r = counts/revolution

125 µs

7.324219 counts/min

187.5 µs

4.882813 counts/min

250 µs

3.662109 counts/min

312.5 µs

2.929688 counts/min

For stepper motors, the
maximum counts/min
value is dependent on the
controller:

• 480 million

counts/min for 7350

• 240 million

counts/min for 7330,
7340, and 7390

±RPM

min

= MIN×1/r

where r = counts/revolution

375 µs

2.441406 counts/min

437.5 µs

2.092634 counts/min

500 µs

1.831055 counts/min

Advertising