Labview code, Figure 12-14. modulo breakpoint using labview, Labview code -24 – National Instruments NI-Motion User Manual

Page 174

Advertising
background image

Chapter 12

Synchronization

NI-Motion User Manual

12-24

ni.com

LabVIEW Code

Figure 12-14. Modulo Breakpoint Using LabVIEW

Figure 12-15. Modulo Breakpoint with RTSI Using LabVIEW

1

Configure Breakpoint

2

Load Breakpoint Modulus

3

Load Breakpoint Position

4

Enable Breakpoint Output

5

Read per Axis Status

6

Motion Error Handler

1

Select Signal

2

Configure Breakpoint

3

Load Breakpoint Modulus

4

Load Breakpoint Position

5

Enable Breakpoint Output

6

Read per Axis Status

7

Motion Error Handler

1

6

3

5

4

2

7

6

5

2

4

1

3

Advertising