NI-Motion User Manual

err = flex_load_rpsps(boardID, axis, NIMC_BOTH,

50.00, 0xFF);

CheckError;

// Start the move

err = flex_start(boardID, axis, 0);

CheckError;

// Wait for move to complete

err = flex_wait_on_event(boardID, 0, NIMC_WAIT,

NIMC_CONDITION_MOVE_COMPLETE, 2/*Indicates axis 1*/,

0, NIMC_MATCH_ALL, 1000 /*time out*/, 0);

CheckError;

// End Program Storage

err = flex_end_store(boardID, 2);

CheckError;

//------------------------------------------------

// Onboard program 3. This onboard program moves axis

one counter //clockwise 5000 counts (steps). This

onboard program is executed //by onboard program one.

//------------------------------------------------

// Begin onboard program storage - program number 3

err = flex_begin_store(boardID, 3);

CheckError;

// Set the operation mode to relative

err = flex_set_op_mode(boardID, axis,

NIMC_RELATIVE_POSITION);

CheckError;

// Load Target Position to move counter clockwise

5000 //counts(steps)

err = flex_load_target_pos(boardID, axis, -5000,

0xFF);

CheckError;

// Load Velocity in RPM

err = flex_load_rpm(boardID, axis, 100.00, 0xFF);

CheckError;

// Load Acceleration and Deceleration in RPS/sec

err = flex_load_rpsps(boardID, axis, NIMC_BOTH,

50.00, 0xFF);

CheckError;

// Start the move

err = flex_start(boardID, axis, 0);