National Instruments NI-Motion User Manual

Page 61

Advertising
background image

Chapter 5

Straight-Line Moves

NI-Motion User Manual

5-6

ni.com

err = flex_load_scurve_time(boardID, axis, 1000,

0xFF);

CheckError;

// Set the operation mode

err = flex_set_op_mode (boardID, axis,

NIMC_ABSOLUTE_POSITION);

CheckError;

// Load Position

err = flex_load_target_pos (boardID, axis, 5000,

0xFF);

CheckError;

// Start the move

err = flex_start(boardID, axis, 0);

CheckError;

do

{

axisStatus = 0;

// Check the move complete status

err = flex_check_move_complete_status(boardID,

axis, 0, &moveComplete);

CheckError;

// Check the following error/axis off status for

the axis

err = flex_read_axis_status_rtn(boardID, axis,

&axisStatus);

CheckError;

// Read the communication status register and

check the modal //errors

err = flex_read_csr_rtn(boardID, &csr);

CheckError;

// Check the modal errors

if

(csr & NIMC_MODAL_ERROR_MSG)

{

err = csr & NIMC_MODAL_ERROR_MSG;

CheckError;

}

}while (!moveComplete && !(axisStatus &

NIMC_FOLLOWING_ERROR_BIT) && !(axisStatus &

NIMC_AXIS_OFF_BIT));

//Exit on move complete/following error/axis off

return

;// Exit the Application