OCU-DP Card User Screens and Settings

Table 3-4. Performance Data Screen Actions

IES

The Input Errored Seconds (IES) field shows the total number of seconds in which any input
errors were detected. Since this is an information-only field, there are no user-selectable
parameters.

ISES

The Input Severely Errored Seconds (ISES) field shows the total number of seconds in which
the input bit error rate exceeded one bit per thousand (1 x 10-

3

). Since this is an

information-only field, there are no user-selectable parameters.

ICSES

The Input Consecutive Severely Errored Seconds (ICSES) field is triggered by the occurrence
of ten consecutive Input Severely Errored Seconds. Once triggered, the ICSES field will
increment (by one) for each elapsed second until the system logs ten consecutive seconds that
are not severely errored. Since this is an information-only field, there are no user-selectable
parameters.

OES

The Output Errored Seconds (OES) field shows the total number of seconds in which any
output errors were detected. This field only applies if the error correction method selected is
BCH. Since this is an information-only field, there are no user-selectable parameters.

OSES

The Output Severely Errored Seconds (OSES) field shows the total number of seconds in
which the output bit error rate exceeded one bit per thousand (1 x 10-

3

). This field only applies

if the error correction method selected is BCH. Since this is an information-only field, there
are no user-selectable parameters.

Action

Function

Refresh

Updates certain time-related information fields that are not automatically
updated (i.e. performance and test data).

Clear

Clears the test screen.

pgUp

Scrolls through data screens from the oldest to the newest.

pgDn

Scrolls through data screens from the newest to the oldest.

Main

Returns to the OCU-DP card main screen.

Advertising