OCU-DP Card

OCU-DP Card User Screens and Settings

ERR COR

The Error Correction setting is used only on the OCU-DP 2 Card. It provides different
methods of error correction, depending on the data Rate selected. The default ERR COR
setting is off. If you choose subrate speeds of 9.6k or less in the Rate setting, the Error
Correction option maj-v (majority voting) is available. Using majority-vote error correction
allows the system to poll the data for errors and decide on the correct data based on the
repeated bit pattern.

The bch error correction option is available for 19.2K only. Bch Error Correction is not
supported on the OCU-DP5 or OCU-DP 10 Card. Maj-v is supported for 2.4, 4.8, and 9.6K.

SECOND

Secondary channel operation allows the DSU/CSU to establish a separate lower-speed data
circuit with the OCU-DP port. When synchronized, this special circuit can be used for testing
and maintenance of the main circuit, or for transmission of other low-speed data. The settings
are on and off.

The secondary channel is transported in the 8th bit position of the DS0 time slot to which the
OCU-DP is assigned. Table 3-3 shows the secondary channel rate associated with the various
primary port rates supported by the card. For a further description of the secondary channel
function, refer to Pub 62310 and TA-TSY 000077 and TA-TSY 000083.

Table 3-3. OCU-DP Primary and Secondary Channel Rates

USER LB

The User Loopback (USER LB) is a specialized code conversion function that is only relevant
in Taiwan and some other countries in the Far East. The options are d and o, neither of which
has any effect in North America.

Primary Port Rate

Secondary Channel Rate

56 kbps

2666 bps

19.2 kbps

1,066 bps

9.6 kbps

533 bps

4.8 kbps

266 bps

2.4 kbps

133 bps