IMACS System Release 5.1.6

Data Cards

Model No.

Running Head

HSU Card User Screens and Settings

HSU Card

Table 1-5. HSU Card Setting Options and Defaults

Notes:

1. The WAN/SRV parameter has three optional choices: wan, serv and user. In wan

mode, the options are w1-1 through w4-2. In serv mode, the option are P1-P3 and in
user mode, the options are U1-U8 (Port 1-4).

2. If the WAN selected above has a CSU or DSX module connected, the values range from

1-24. If a CEPT module is installed the values are 1-31.

3. These options are only valid if the Loopback Generation Mode selected is dds. If the

Loopback Generation Mode is v.54 or ft1, then the LB GEN options are off and on.

4. This is an information-only field, there are no user selections.

5. DTE mode is only for HSU-T (8203, 8214).

6. Displays only for HSU-AD 530/35 (8213).

7. Displays only for HSU*4E 530/35 (8216). For other models the parameter will display

CLOCK PLRTY.

Parameter

User Options

Notes

Default

STATE

stdby actv

stdby

WAN/SRV

wan serv user

1

w1-1

MODE

dce dte

5

dce

TS

table

2

table

RATE

64k 56k

56k

TX CLOCK

int ext

int

Tx CLOCK PLRTY norm inv

7

norm

DATA PLRTY

norm inv

norm

CTS

perm rlocal ignor local

perm

CTS DELAY

0 30 60 100

0

LOCAL LB

off dte net

off

LB GEN MODE

dds v.54 ft1

dds

LB GEN

off ocu csu (csu-1, csu-2) dsu ds0 (ds0-1, ds0-2)

3

off

LB DET

w/to on off

w/to

ISDN CONN

no

4

no

EER

off on none 10e

-4

- 10e

-9

6

none

Rx CLOCK PLRTY norm inv

7

norm