Bri card bri card user screens and settings – Zhone Technologies 900 User Manual

Page 127

Advertising
background image

Data Cards

IMACS System Release 5.1.6

5-13

BRI Card

BRI Card User Screens and Settings

Table 5-6. BRI-ST*8 Card Configuration Option Settings and Defaults

Notes:

1. SRV functions (P1, P2 and P3) may be activated from the Conversion Screen when an

ADPCM server is installed.

2. D-Channels will only show if brite is selected for Type.

3. These options are only available for LB GEN Modes of ddsT and ddsN. See LB GEN

paragraph below.

TERMINAL

For the BRI U*8 and BRI-SC U*8 cards:

conVert

The Conversion feature allows the B channels to be used with ADPCM
compression features.

Eoc

Embedded Operations Channel (not yet supported)

Ntu

Network Terminating Unit programming. (not applicable to 8262).

Test

Initiates and monitors testing of all BRI card ports. See Test section.

Perf

Shows the performance statistics for the port highlighted. See the Performance
Monitoring section. Not implemented in S/T card.

Main

Returns to the main terminal screen. If changes are made to settings and not
saved, users will be prompted to save or lose changes.

Parameter

User Options

Notes

Default

STATE

stdby actv

stdby

TERMINAL

nt-pp nt-sb nt-eb te

nt-pp

TYPE

lease brite

lease

B MODE

none B1 B2 B1+B2 128K

none

B1 WAN/SRV

none w1-1 w1-2 w2-1 w2-2 w3-1 w3-2 w4-1
w4-2 P1 P2 P3

1

none

B1 TS

n/a 01 to 24 01 to 31

n/a

B2 WAN/SRV

none w1-1 w1-2 w2-1 w2-2 w3-1 w3-2 w4-1
w4-2 P1 P2 P3

1

none

B2 TS

n/a 01 to 24 01 to 31

n/a

D WAN

none w1-1 w1-2 w2-1 w2-2 w3-1 w3-2 w4-1
w4-2 P1 P2 P3

2

none

D TS

n/a 01 to 24 01 to 31

2

n/a

D SUBCHAN

n/a off 1 2 3 4

2

n/a

LOCAL LB

off ta net

off

LB CHAN

B1 B2 B1+B2

B1

LBGEN MD

ddsT ddsN v54T v54N ft1T ft1N

ddsT

LB GEN

off B1ocu B1csu B1ds0 B1dsu B2ocu B2csu
B2ds0 B2dsu

3

off

RCVE

n/a

n/a

TR COND

n/a

n/a

Advertising