Data Cards

IMACS System Release 5.1.6

3-15

OCU-DP Card

OCU-DP Card User Screens and Settings

Table 3-5 lists the actions you can perform from the Test Screen. These appear on the bottom
highlighted line of the screen. Table 3-6 lists the settings controlled on this screen along with
their possible and default values.

Table 3-5. Test Screen Actions

Table 3-6. Test Screen Option Settings and Defaults

BERT

The Bit Error Rate Tester (BERT) sends a data pattern and measures the bit error rate (BER)
on the selected OCU-DP port. The patterns that can be selected are off, mark (all ones), space
(all zeros), 1:1 (1010), 1:7 (0100-0000), 511 (511 test pattern), 2047 (2047 test pattern) and
qrss (quasi-random pseudo signal).

Action

Function

Save

Saves changes to settings.

Undo

Returns all settings to the last saved state.

Refresh

Since the data in this screen is not updated in real time, the Refresh
command is used to obtain the latest statistics.

insertErr

Allows you to manually insert a single error into a clear data signal.

Test

Clears the Test Screen.

Main

Returns to the OCU-DP Card Main Screen. If changes are made to settings
and not saved, you will be prompted to save or lose changes.

Parameter

User Options

Default

BERT

off mark space 1:1 1:7 511 2047 qrss

off

DIR

net user

net

DATA

pri sec

pri

SYNC

information only–no user options

BE

information only–no user options

ES

information only–no user options

SES

information only–no user options

CSES

information only–no user options

OSS

information only–no user options

BER

information only–no user options

ELAP

information only–no user options

LB ST

information only–no user options

4W DDS

information only–no user options

Advertising