IMACS System Release 5.1.6

5-33

BRI Card

BRI Card User Screens and Settings

Notes:

1. The loc and loc_net options are included to support manual loopback override at the

NTU site.

2. These parameters are not supported in this release.

TEST

Choosing net allows you to set loopback configuration to the network loop (between the BRI
card and NTU). The default is off.

TIMER

This indicates whether the loopback configuration is set to time out, or whether it is ongoing.
The options are off and on (default). When this option is on, the loopback timeout is set to 15
minutes. This is a read-only parameter; it is not user-selectable.

STATUS

This parameter indicates the direction of the loopback configuration. The options are off
(default), loc (local loop), net (network loop), and loc_net (local and network loops). The loc
and loc_net parameters are included in the event that the local loopback testing is activated
manually by selecting a switch on the front panel of the NTU. This is a read-only parameter;
it is not user-selectable.

ERROR

This parameter is not supported in this release.

TOTAL

This parameter is not supported in this release.

TEST

off net

off

TIMER

off on

on

STATUS

off loc net loc_net

1

off

ERROR

n/a

2

n/a

TOTAL

n/a

2

n/a