1 introduction, 2 ds0-dp card description, 1 ds0-dp 4 card description (825460) – Zhone Technologies 900 User Manual

Page 109: 1 card jumper/switch settings, 2 installing the card, Introduction -1, Chapter 4 ds0-dp card

Advertising
background image

Data Cards

IMACS System Release 5.1.6

4-1

DS0-DP Card

Introduction

Chapter 4
DS0-DP Card

4.1

Introduction

This chapter provides installation, configuration, and troubleshooting information for the DS0
Dataport (DS0-DP) Card. This card is labeled as the DS0-DP 4 card on its faceplate ejector.

4.2

DS0-DP Card Description

4.2.1

DS0-DP 4 Card Description (825460)

The DS0-DP 4 Card Contradirectional/Codirectional Data Unit (DS0-DP/G.703) provides a
64 kbps interface to a DS0 time slot of a T1 or E1 network. Since the byte alignment of the 64
kbps data stream to the time slot is essential, the interface provides a 64 kbps bit clock and an
8 kHz byte clock in the DS0-DP mode.

Notice!

UL STATEMENT

OPERATION OF THIS INTERFACE IS LIMITED TO INTRA-BUILDING

CONNECTIONS ONLY

4.2.1.1

Card Jumper/Switch Settings

The DS0-DP 4 Card does not have any jumpers or switches on its mainboard.

4.2.1.2

Installing the Card

Install the DS0-DP 4 Card into any user card slot. These slots are U1 to U8 on the two-sided
chassis and front-loading chassis with power supplies on top, and P1 to P4 or W1 to W4 on
the front-loading chassis with power supplies on the side.