Zhone Technologies 900 User Manual

Page 38

Advertising
background image

1-26

IMACS System Release 5.1.6

Data Cards

Model No.

Running Head

HSU Card User Screens and Settings

HSU Card

CSES

The Consecutive Severely Errored Seconds (CSES) field is triggered by the occurrence of ten
consecutive Severely Errored Seconds. Once triggered, this field will increment (by one) for
each elapsed second until the system logs ten consecutive non-Severely Errored Seconds. This
is an information-only field; it is not user-configurable.

OSS

The Out of Synchronization Seconds (OSS) field indicates the number of seconds that the
HSU BERT has been out of synchronization. This is an information-only field; it is not
user-configurable.

BER

The Bit Error Rate (BER) field indicates the rate at which errors are being logged. The system
calculates BER by dividing the number of bit errors (BE) by the total number of bits
transmitted during the test. This is an information-only field; it is not user-configurable.

ELAP

The Elapsed time (ELAP) setting indicates the running tally of the total number of seconds
during the test. This is an information-only field; it is not user-configurable.

RTS

The Request To Send (RTS) field indicates the current status of the RTS control lead. The two
values that can be displayed are on and off. This is an information-only field; it is not
user-configurable.

DTR

The Data Terminal Ready (DTR) field indicates the current status of the DTR control lead.
The two values that can be displayed are on and off. This is an information-only field; it is not
user-configurable.

The DTR field will always indicate on for the HSU 35 Card (Revision A and earlier), but it
will toggle between off and on all other HSU Cards.