Barcode options – Printronix N7000 H-Series Cartridge Ribbon Printer User Manual

Page 126

Advertising
background image

126

Chapter

4

IGP/PGL Emulation

Barcode Options

The following sub-options help define specific options regarding barcode
printing.

UPC Descenders

This parameter allows you to print barcode descenders when human
readable data is not present in the UPC/EAN barcodes.

Always

(default). UPC/EAN barcodes are printed with descenders, even

if there is no human readable data.

Never

. UPC/EAN barcodes are printed without descenders if there is no

human readable data.

Only with PDF

. UPC/EAN barcodes are printed with descenders only

when the PDF command is present.

Optimized Ratio

This option selects different barcode ratios for certain barcodes including
Code 39 and I-2/5. It is included for compatibility with the IGP-X00 printers.

Disable

(default). Use standard barcode ratios.

Enable

. Select the alternate barcode ratios.

I-2/5 Selection

This option is added to be compatible with a special IGP-X00 customization.
Usually, if I-2/5 barcodes have an odd number of digits, a leading zero is
inserted in front of the data. However, this special IGP-X00 customization
gives you the option of adding a space character at the end of the barcode
instead.

Leading Zero

(default). A leading zero is inserted in front of the printable

data field.

Trailing Space

. A space is inserted at the end of the printable data field

and a zero is encoded with the corresponding space in the end of the
barcode.

X2 DPD

. When selected, an I-2/5 barcode with an X2 magnification will

use the specially configured ratios 3:3:6:5 rather than 3:6:9:12 for
compatibility issues.

Modulo 7 CD

. The I-2/5 barcode uses a modulo 7 check digit instead of

the default modulo 10 check digit.

AI 00 Spaces

This option is designated for EAN/UCC-128 barcodes whose application
identifier (AI) is 00.

Disable

(default). The printable data field is printed with the AI enclosed

in parentheses. This is the standard EAN/UCC-128 format.

Enable

. The printable data field is printed with the UCC fields separated

by spaces. This option is IGP-X00 compatible.

Advertising