Printronix N7000 H-Series Cartridge Ribbon Printer User Manual

Page 193

Advertising
background image

N7000 STD ASCII Printers Fault Messages

193

E33 WRITE BP
See User Manual

Yes

An illegal or unsupported
instruction was attempted
in the application
program.

1.

Cycle Power. Run the print job
again. If the message appears,
load the latest emulation
software.

2.

Cycle power. Run the print job
again. If the message appears,
record the display message
and send it to your next higher
support facility.

E34 TRACE CMPLT
See User Manual

Yes

An illegal or unsupported
instruction was attempted
in the application
program.

1.

Cycle Power. Run the print job
again. If the message appears,
load the latest emulation
software.

2.

Cycle power. Run the print job
again. If the message appears,
record the display message
and send it to your next higher
support facility.

E99 UNKNOWN INT
See User Manual

Yes

An illegal or unsupported
instruction was attempted
in the application
program.

1.

Cycle Power. Run the print job
again. If the message appears,
load the latest emulation
software.

2.

Cycle power. Run the print job
again. If the message appears,
record the display message
and send it to your next higher
support facility.

ERROR OCCURRED
FLUSHING QUEUES*

Yes

An interim message that
displays while the printer
discards host data it
cannot use because a
fault condition exists.
While this message
displays, the asterisk (*)
rotates.

Wait. When the asterisk (*) stops
rotating, a different fault message
will appear: troubleshoot the final
message.

ERROR: CPLD NOT
PROGRAMMED

No

The Complex
Programmable Logic
Device (CPLD) on the
controller board is not
programmed. The EC
cannot read the version
bits in the CPLD which
tell the EC which
configuration version is
installed.

Contact your authorized service

representative.

1

Table 12. N7000 STD ASCII LCD Fault Messages Troubleshooting

Displayed Message

Can User

Correct?

Explanation

Solution

Advertising