Printronix N7000 H-Series Cartridge Ribbon Printer User Manual

Page 197

Advertising
background image

N7000 STD ASCII Printers Fault Messages

197

H01: PCI J12
See User Manual

No

The controller board is
not communicating with
the PCI card in PCI slot
J12. This could indicate a
bad PCI card, poor
connection, or problem in
the PCI bus.

Contact your authorized service

representative.

1

H02: PCI J13
See User Manual

No

The controller board is
not communicating with
the PCI card in PCI slot
J13. This could indicate a
bad PCI card, poor
connection, or problem in
the PCI bus.

Contact your authorized service

representative.

1

<Online, etc...>

Half Speed Mode

No

Status message: The
controller samples the
operating temperature of
key components of the
print mechanism. When
higher than normal
temperatures are sensed,
the print speed is
automatically reduced by
50% and the message
sent the LCD. When the
components cool down,
the print speed returns to
100% and the message
clears.

No action is required. If the
message appears often, contact
your authorized service

representative.

1

HAM. COIL OPEN*

No

Hammer Coil Open.
Electrical malfunction of
one or more hammer
coils.

Contact your authorized service

representative.

1

HAMMER COIL BAD*

#, #, #, ...etc

No

Hammer coil # failed
current test at power up.

Contact your authorized service

representative.

1

HAMMER SHORT*

See User Manual

No

Electrical malfunction of
one or more hammer
coils.

Contact your authorized service

representative.

1

HB NOT INSTALLD*

No

Hammer Bank Not
Installed. Self-test
routines do not detect
hammer coils at printer
start-up.

Contact your authorized service

representative.

1

Table 12. N7000 STD ASCII LCD Fault Messages Troubleshooting