N7000 STD ASCII Printers Fault Messages

181

B35 STATUS:

WAITING FOR EC
STATUS

N/A

Status message: the DC
on the controller board is
waiting for
communication with the
EC. If this message does
not clear witin a few
seconds there is an
electrical or electronic
problem on the controller
board.

Cycle power to see if the message
clears, if not, contact your

authorized service representative.

1

B40 ERROR: SDRAM
EEPROM CKSUM
BAD*

No

Flash memory has not
passed boot initialization
tests.

Cycle power to see if the message
clears, if not, contact your

authorized service representative.

1

B41 ERROR: DIM
MEMORY NOT
SDRAM*

No

The DRAM DIMM
installed on the controller
board is not Synchronous
DRAM (SDRAM).

Cycle power to see if the message
clears, if not, contact your

authorized service representative.

1

B42 ERROR: SDRAM
ROWS NOT
ALLOWED*

No

Printer boot initialization
tests detect incorrect
SDRAM.

Cycle power to see if the message
clears, if not, contact your

authorized service representative.

1

B43 ERROR: SDRAM
TOO MANY BANKS*

No

Printer boot initialization
tests detect incorrect
SDRAM.

Cycle power to see if the message
clears, if not, contact your

authorized service representative.

1

B44 ERROR: SDRAM
NOT 64 BITS WIDE*

No

Printer boot initialization
tests detect incorrect
SDRAM.

Cycle power to see if the message
clears, if not, contact your

authorized service representative.

1

B45 ERROR: SDRAM
IS WRONG VOLTAGE*

No

Printer boot initialization
tests detect incorrect
SDRAM.

Cycle power to see if the message
clears, if not, contact your

authorized service representative.

1

B46 ERROR: SDRAM
HAS MIXED SIZES*

No

Printer boot initialization
tests detect incorrect
SDRAM.

Cycle power to see if the message
clears, if not, contact your

authorized service representative.

1

B47 ERROR: SDRAM
LARGER THAN 256M*

No

Printer boot initialization
tests detect incorrect
SDRAM.

Cycle power to see if the message
clears, if not, contact your

authorized service representative.

1

B49 ERROR: SDRAM
# LOGICAL BANKS*

No

Printer boot initialization
tests detect incorrect
SDRAM.

Cycle power to see if the message
clears, if not, contact your

authorized service representative.

1

B50 ERROR: SDRAM
LOGIC COMB BANKS*

No

SDRAM DIMM is not
compatible with the
computer. SDRAM DIMM
may not be properly
installed.

Cycle power to see if the message
clears, if not, contact your

authorized service representative.

1

Table 12. N7000 STD ASCII LCD Fault Messages Troubleshooting

Displayed Message

Can User

Correct?

Explanation

Solution